RFtyt 34mhz-31.0ghz RF pad izolatora | |||||||||
Model | Raspon frekvencije (MHz) | Širina pojasa (Max) | Gubitak umetanja (dB) | Izolacija (dB) | VSWR (Max) | Napredna snaga (W) | ObrnutiSnaga (W) | Dimenzija Wxlxh (mm) | List |
WG6466H | 30-40 | 5% | 2.00 | 18.0 | 1.30 | 100 | 20/100 | 64.0 * 66.0 * 22.0 | |
WG6060E | 40-400 | 50% | 0,80 | 18.0 | 1.30 | 100 | 20/100 | 60.0 * 60.0 * 25.5 | |
WG6466E | 100-200 | 20% | 0,65 | 18.0 | 1.30 | 300 | 20/100 | 64.0 * 66.0 * 24.0 | |
Wg5050x | 160-330 | 20% | 0,40 | 20.0 | 1,25 | 300 | 20/100 | 50.8 * 50.8 * 14.8 | |
Wg4545x | 250-1400 | 40% | 0,30 | 23,0 | 1.20 | 300 | 20/100 | 45.0 * 45.0 * 13.0 | |
WG4149A | 300-1000 | 50% | 0,40 | 16.0 | 1.40 | 100 | 20 | 41.0 * 49.0 * 20.0 | |
Wg3538x | 300-1850 | 30% | 0,30 | 23,0 | 1.20 | 300 | 20 | 35.0 * 38.0 * 11.0 | |
Wg3546x | 300-1850 | 30% | 0,30 | 23,0 | 1.20 | 300 | 20dB 30db 100w | 35.0 * 46.0 * 11.0 | 20dB pdf 30dB pdf 100W PDF |
Wg2525x | 350-4300 | 25% | 0,30 | 23,0 | 1.20 | 200 | 20 | 25.4 * 25.4 * 10.0 | |
Wg2532x | 350-4300 | 25% | 0,30 | 23,0 | 1.20 | 200 | 20dB 30db 100w | 25.4 * 31.7 * 10.0 | 20dB pdf 30dB pdf 100W PDF |
Wg2020x | 700-4000 | 25% | 0,30 | 23,0 | 1.20 | 100 | 20 | 20.0 * 20.0 * 8.6 | |
Wg2027x | 700-4000 | 25% | 0,30 | 23,0 | 1.20 | 100 | 20dB 30db 100w | 20.0 * 27.5 * 8.6 | 20dB pdf 30dB pdf 100W PDF |
Wg1919x | 800-5000 | 25% | 0,30 | 23,0 | 1.20 | 100 | 20 | 19.0 * 19.0 * 8.6 | |
Wg1925x | 800-5000 | 25% | 0,30 | 23,0 | 1.20 | 100 | 20dB 30db 100w | 19.0 * 25.4 * 8.6 | 20dB pdf 30dB pdf 100W PDF |
Wg1313t | 800-7000 | 25% | 0,30 | 23,0 | 1.20 | 60 | 20 | 12.7 * 12.7 * 7.2 | PDF (kroz otvor) |
WG1313M | 800-7000 | 25% | 0,30 | 23,0 | 1.20 | 60 | 20 | 12.7 * 12.7 * 7.2 | PDF (otvor za vijak) |
WG6466K | 950-2000 | Pun | 0,70 | 17.0 | 1.40 | 100 | 20/100 | 64.0 * 66.0 * 26.0 | |
WG5050A | 1.35-3.0 GHz | Pun | 0,70 | 18.0 | 1.30 | 150 | 20/100 | 50.8 * 49.5 * 19.0 | |
WG4040A | 1.6-3.2 GHz | Pun | 0,70 | 17.0 | 1.35 | 150 | 20/100 | 40.0 * 40.0 * 20.0 | |
Wg3234a Wg3234b | 2.0-4.2 GHz | Pun | 0,50 | 18.0 | 1.30 | 150 | 20 | 32.0 * 34.0 * 21.0 | PDF (otvor za vijak) (kroz otvor) |
Wg3030b | 2.0-6.0 GHz | Pun | 0,85 | 12.0 | 1,50 | 50 | 20 | 30,5 * 30,5 * 15,0 | |
Wg2528c | 3.0-6.0 GHz | Pun | 0,50 | 20.0 | 1,25 | 100 | 20/100 | 25.4 * 28.0 * 14.0 | |
Wg2123b | 4.0-8.0 GHz | Pun | 0,60 | 18.0 | 1.30 | 50 | 10 | 21.0 * 22.5 * 15.0 | |
Wg1623d | 5.0-7.3 GHz | 20% | 0,30 | 20.0 | 1,25 | 100 | 5 | 16.0 * 23.0 * 9.7 | |
WG1220D | 5,5-7,0 GHz | 20% | 0,40 | 20.0 | 1.20 | 50 | 5 | 12.0 * 20.0 * 9.5 | |
Wg0915d | 6.0-18.0 GHz | 40% | 0,40 | 20.0 | 1,25 | 30 | 5 | 8.9 * 15.0 * 7.8 | |
Wg1622b | 6.0-18.0 GHz | Pun | 1,50 | 9,50 | 2.00 | 30 | 5 | 16.0 * 21.5 * 14.0 | |
Wg1319c | 8.0-18.0 GHz | 40% | 0,70 | 16.0 | 1,45 | 10 | 10 | 12.0 * 15.0 * 8.6 | |
Wg1017c | 18.0-31.0 GHz | 38% | 0,80 | 20.0 | 1.35 | 10 | 2 | 10.2 * 17.6 * 11.0 |
Pad izolatora je elektronički uređaj koji se koristi za postizanje izolacije RF signala u krugu. Pad izolator ima specifičnu frekvencijsku propusnost. U okviru pass trake signali se mogu glatko prenijeti iz RX Port 1 do antene 2 u navedenom smjeru. Međutim, zbog svoje izolacije, signali iz luke antene 2 ne mogu se prenijeti na TX port 1. Stoga ima funkciju jednosmjernog prijenosa, poznat i kao jednosmjerni transformator.
Izolator pad sastoji se od šupljine, rotirajućeg magneta, unutrašnjeg provodnika i pristrasno magnetsko polje. Dvije portove zavarivanja unutrašnjeg provodnika strše izvana iz vanjske strane šupljine, čineći ga pogodnim za kupce za zavarivanje sa pločom. Općenito, pad izolatora imaju rupe za ugradnju kroz rupe ili navojne rupe, čineći ga pogodnim za kupce za instaliranje.
Pad izolatora uglavnom se koriste za zaštitu prednjih uređaja, a najnižim aplikacijom je zaštita cijev pojačala u RF pojačalama (pojačani signal pojačala zvuka, a u slučaju antene ne može se ogledati na prednji kraj izolatora, osiguravajući da cijev pojačala za napajanje nije izgorelo).
Učitavanje porta pad izolatora također ima 20DB ili 30DB prigušivač čipova za povezivanje. Funkcija ovog prigušivača čipa je otkrivanje neusklađenosti antene luke. Ako se pojavi neusklađenost luke antene, signal se prenosi na prigušivač čipa, a nakon prigušivanja od 20 dB ili 30db signal se propadalo u neobično slabo stanje. A inženjeri mogu koristiti ovaj slab signal za upravljanje prednjim krugom, poput isključivanja i drugih operacija.